﻿{"id":34515,"date":"2015-09-26T22:57:42","date_gmt":"2015-09-26T20:57:42","guid":{"rendered":"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/?p=34515"},"modified":"2015-09-26T22:58:58","modified_gmt":"2015-09-26T20:58:58","slug":"enfermeria-monitorizacion-bis","status":"publish","type":"post","link":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/","title":{"rendered":"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)"},"content":{"rendered":"<h1 style=\"text-align: left;\"><\/h1>\n<h1 style=\"text-align: left;\"><strong>Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)<\/strong><\/h1>\n<p style=\"text-align: justify;\"><strong>Resumen:<\/strong><\/p>\n<p style=\"text-align: justify;\">El \u00edndice biesprectal (BIS) es un sistema no invasivo de monitorizaci\u00f3n neurofisiol\u00f3gico del SNC, para medir el nivel de sedaci\u00f3n y consciencia.<\/p>\n<p style=\"text-align: justify;\">Deriva del estudio de la se\u00f1al el\u00e9ctrica cortical (EEG) y tras un an\u00e1lisis posterior ofrece un valor num\u00e9rico que oscila entre 0 y 100.<\/p>\n<p style=\"text-align: justify;\"><!--more--><\/p>\n<p style=\"text-align: justify;\"><strong>Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)<\/strong><\/p>\n<p style=\"text-align: justify;\">Autoras:<\/p>\n<p style=\"text-align: justify;\">Ver\u00f3nica Pardo Perez<\/p>\n<p style=\"text-align: justify;\">Lorena Igal Navascues<\/p>\n<p style=\"text-align: justify;\"><strong>Palabras clave: <\/strong>biespectral, BIS, monitor, sensor, sedaci\u00f3n<\/p>\n<p style=\"text-align: justify;\"><strong>Palabras claves en ingles:<\/strong><\/p>\n<p style=\"text-align: justify;\">Biespectral, BIS, monitor, sensor, sedation<\/p>\n<p style=\"text-align: justify;\"><strong>Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)<\/strong><\/p>\n<p style=\"text-align: justify;\"><strong>Introducci\u00f3n<\/strong><\/p>\n<p style=\"text-align: justify;\">El \u00edndice biespectral (BIS) es un sistema no invasivo de monitorizaci\u00f3n neurofisiol\u00f3gico del sistema nervioso central (SNC), para medir el nivel de sedaci\u00f3n y consciencia.<\/p>\n<p style=\"text-align: justify;\">Deriva del estudio de la se\u00f1al el\u00e9ctrica cortical (EEG) y tras un an\u00e1lisis posterior ofrece un valor num\u00e9rico que oscila entre 0 y 100.<\/p>\n<p style=\"text-align: justify;\"><strong>Descripci\u00f3n del sistema<\/strong><\/p>\n<ol style=\"text-align: justify;\">\n<li>Monitor con modulo medici\u00f3n BIS o monitor BIS. (Foto 1)<\/li>\n<\/ol>\n<ul style=\"text-align: justify;\">\n<li>\u00c1rea num\u00e9rica: se muestra un valor del BIS con n\u00fameros. Los valores oscilan entre 0 y 100 y entre 40-60 indican un grado adecuado de hipnosis profunda. (foto 2)<\/li>\n<li>\u00cdndice de calidad de la se\u00f1al: informa de la calidad de la se\u00f1al del electroencefalograma (EEG) que recibe el monitor, cuando todas las barras est\u00e1n completas corresponda a una buena calidad (100%).<\/li>\n<li>Onda de EEG.<\/li>\n<li>Tasa de supresi\u00f3n (TS): presentada como una tanto por ciento. Su valor \u00f3ptimo debe ser lo m\u00e1s pr\u00f3ximo a cero posible.<\/li>\n<\/ul>\n<ol style=\"text-align: justify;\" start=\"2\">\n<li>Cable BIS: cable de fibra \u00f3ptica que transmite la se\u00f1al recogida por los electrodos.<\/li>\n<li>Sensor BIS. (Foto 3): consta de 4 electrodos numerados, no contiene l\u00e1tex, es desechable y se recomienda la utilizaci\u00f3n a 24 horas aproximadamente.<\/li>\n<\/ol>\n<p style=\"text-align: justify;\"><strong>Colocaci\u00f3n:<\/strong><\/p>\n<ul style=\"text-align: justify;\">\n<li>Lavado de manos.<\/li>\n<li>Colocaci\u00f3n de guantes.<\/li>\n<li>Preparaci\u00f3n material y monitor.<\/li>\n<li>Informar al paciente en el caso de que este consciente.<\/li>\n<li>Encender el monitor.<\/li>\n<li>Limpiar la frente con una gasa seca, en el caso de grasa o l\u00edquidos org\u00e1nicos hacerlo con una gasa impregnada en alcohol.<\/li>\n<li>Abrir el envase del sensor (no extraerlo antes de su colocaci\u00f3n para evitar que se seque la gelatina de los electrodos).<\/li>\n<li>Colocar el sensor BIS: (foto 4)<\/li>\n<li>Electrodo 1: en la l\u00ednea media frontal, 5 cm por encima de la ra\u00edz de la nariz.<\/li>\n<li>Electrodo 2: correlativo al electrodo 1.<\/li>\n<li>Electrodo 4: en la zona externa del arco superciliar, por encima\/junto a la terminaci\u00f3n de la ceja.<\/li>\n<li>Electrodo 3: zona temporal derecha o izquierda entre el \u00e1ngulo externo del ojo y la ra\u00edz del cabello. Poner especial cuidado en no situar el electrodo justo la arteria temporal, pues se producir\u00edan artefactos.<\/li>\n<li>Presionar los bordes de los cuatro sensores durante 5 segundos.<\/li>\n<li>Conectar el sensor al cable BIS.<\/li>\n<li>Registrar en la grafica los valores de BIS, EMG, TS e ICS si procede<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><!--nextpage--><\/p>\n<p style=\"text-align: justify;\"><strong>Recomendaciones<\/strong><\/p>\n<ul style=\"text-align: justify;\">\n<li>Habr\u00e1 que valorar en cada caso los posibles factores que puedan alterar el BIS (hipoglucemias, shock hipovol\u00e9mico grave, parada cardiorrespiratoria&#8230;)<\/li>\n<li>En el caso de que se haya secado la gelatina se puede utilizar gel conductor.<\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><strong>Conclusi\u00f3n<\/strong><\/p>\n<p style=\"text-align: justify;\">El profesional de Enfermer\u00eda debe aprender a utilizar correctamente el equipo BIS para la obtenci\u00f3n de unos resultados de calidad.<\/p>\n<p style=\"text-align: justify;\"><strong>FOTOS<\/strong><\/p>\n<p style=\"text-align: justify;\">Foto 1. Monitor BIS<\/p>\n<figure id=\"attachment_34516\" aria-describedby=\"caption-attachment-34516\" style=\"width: 390px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/1-monitor-BIS.jpg\"><img decoding=\"async\" class=\"size-full wp-image-34516\" src=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/1-monitor-BIS.jpg\" alt=\"monitor-BIS\" width=\"400\" height=\"189\" srcset=\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/1-monitor-BIS.jpg 400w, https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/1-monitor-BIS-300x142.jpg 300w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a><figcaption id=\"caption-attachment-34516\" class=\"wp-caption-text\">Monitor BIS<\/figcaption><\/figure>\n<p style=\"text-align: justify;\">Foto 2. Niveles BIS<\/p>\n<figure id=\"attachment_34517\" aria-describedby=\"caption-attachment-34517\" style=\"width: 390px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/2-niveles-BIS.jpg\"><img decoding=\"async\" class=\"size-full wp-image-34517\" src=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/2-niveles-BIS.jpg\" alt=\"niveles-BIS\" width=\"400\" height=\"468\" srcset=\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/2-niveles-BIS.jpg 400w, https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/2-niveles-BIS-256x300.jpg 256w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a><figcaption id=\"caption-attachment-34517\" class=\"wp-caption-text\">Niveles BIS<\/figcaption><\/figure>\n<p style=\"text-align: justify;\">Foto 3. Sensor BIS<\/p>\n<figure id=\"attachment_34518\" aria-describedby=\"caption-attachment-34518\" style=\"width: 390px\" class=\"wp-caption aligncenter wp-more-tag mce-wp-nextpage\"><a href=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/3-colocacion-sensor-BIS.jpg\"><img decoding=\"async\" class=\"size-full wp-image-34518\" src=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/3-colocacion-sensor-BIS.jpg\" alt=\"sensor-BIS\" width=\"400\" height=\"209\" srcset=\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/3-colocacion-sensor-BIS.jpg 400w, https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/3-colocacion-sensor-BIS-300x157.jpg 300w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><\/a><figcaption id=\"caption-attachment-34518\" class=\"wp-caption-text\">Sensor BIS<\/figcaption><\/figure>\n<p style=\"text-align: justify;\">Foto 4. Colocaci\u00f3n sensor BIS<\/p>\n<figure id=\"attachment_34519\" aria-describedby=\"caption-attachment-34519\" style=\"width: 378px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg\"><img decoding=\"async\" class=\"size-full wp-image-34519\" src=\"http:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg\" alt=\"colocacion-sensor-BIS\" width=\"388\" height=\"386\" srcset=\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg 388w, https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS-150x150.jpg 150w, https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS-300x298.jpg 300w\" sizes=\"(max-width: 388px) 100vw, 388px\" \/><\/a><figcaption id=\"caption-attachment-34519\" class=\"wp-caption-text\">Colocaci\u00f3n sensor BIS<\/figcaption><\/figure>\n<p style=\"text-align: justify;\"><strong>Bibliograf\u00eda<\/strong><\/p>\n<ul>\n<li style=\"text-align: justify;\"><strong>Punjasawadwong Y, A Phongchiewboon, Bunchungmongkol N<\/strong>. \u00cdndice biespectal para mejorar la administraci\u00f3n de anestesia y la recuperaci\u00f3n postoperatoria. Base de datos Cochrane de Revisiones Sist\u00e9micas 2007, (4) n: CD003843<\/li>\n<li style=\"text-align: justify;\"><strong>Escudero D, Otero J, Mu\u00f1iz G, Parra D, Cofi\u00f1o L, Tabeada F<\/strong> (2005). Detecci\u00f3n de muerte encef\u00e1lica mediante monitorizaci\u00f3n BIS (\u00edndice biespectral). Medicina Intensiva. 29: 272-278.<\/li>\n<li style=\"text-align: justify;\"><strong>Pardo C, Mu\u00f1oz T, Chamorro C<\/strong>; analgesia and sedation Work Group of SEMICYUC. Monitoring pain:recommendations of the Analgesia and Sedation Work Group of SEMICYUC. Med Intensiva. 2006;30:379-85.<\/li>\n<li style=\"text-align: justify;\"><strong>F\u00e9lix Buis\u00e1n, Nuria Ruiz<\/strong>; Grupo de trabajo de la Sociedad Castellano-leonesa de Anestesiolog\u00eda, Preanimaci\u00f3n y Terap\u00e9utica del Dolor (SOCLARTD). \u00cdndice Biespectral (BIS) para monitorizaci\u00f3n de la consciencia en anestesia y cuidados cr\u00edticos: gu\u00eda de pr\u00e1ctica cl\u00ednica. Valladolid. SOCLARTD, 2008.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS) Resumen: El \u00edndice biesprectal (BIS) es un sistema no invasivo de monitorizaci\u00f3n neurofisiol\u00f3gico del SNC, para medir el nivel de sedaci\u00f3n y consciencia. Deriva del estudio de la se\u00f1al el\u00e9ctrica cortical (EEG) y tras un an\u00e1lisis posterior ofrece un valor num\u00e9rico que oscila entre 0 &#8230; <\/p>\n<p class=\"read-more-container\"><a title=\"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)\" class=\"read-more button\" href=\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#more-34515\" aria-label=\"Leer m\u00e1s sobre Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)\">Leer m\u00e1s<\/a><\/p>\n","protected":false},"author":2,"featured_media":34519,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[83],"tags":[6408,6409,6410,4650,6411],"class_list":["post-34515","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-enfermeria","tag-biespectral","tag-bis","tag-monitor","tag-sedacion","tag-sensor","no-featured-image-padding"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)<\/title>\n<meta name=\"description\" content=\"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS) Resumen: El \u00edndice biesprectal (BIS) es un sistema no invasivo de monitorizaci\u00f3n\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/\" \/>\n<link rel=\"next\" href=\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/2\/\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Redacci\u00f3n Revista\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"ScholarlyArticle\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/\"},\"author\":{\"name\":\"Redacci\u00f3n Revista\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/person\/aff35293bfdd1e8bb11bc1d216ac2c6e\"},\"headline\":\"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)\",\"datePublished\":\"2015-09-26T20:57:42+00:00\",\"dateModified\":\"2015-09-26T20:58:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/\"},\"wordCount\":761,\"publisher\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg\",\"keywords\":[\"biespectral\",\"BIS\",\"monitor\",\"sedaci\u00f3n\",\"sensor\"],\"articleSection\":[\"Enfermer\u00eda\"],\"inLanguage\":\"es\"},{\"@type\":[\"WebPage\",\"ItemPage\"],\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/\",\"url\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/\",\"name\":\"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)\",\"isPartOf\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg\",\"datePublished\":\"2015-09-26T20:57:42+00:00\",\"dateModified\":\"2015-09-26T20:58:58+00:00\",\"description\":\"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS) Resumen: El \u00edndice biesprectal (BIS) es un sistema no invasivo de monitorizaci\u00f3n\",\"breadcrumb\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage\",\"url\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg\",\"contentUrl\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg\",\"width\":388,\"height\":386,\"caption\":\"Colocaci\u00f3n sensor BIS\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Inicio\",\"item\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Enfermer\u00eda\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#website\",\"url\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/\",\"name\":\"Revista Electr\u00f3nica de PortalesMedicos.com\",\"description\":\"ISSN 1886-8924 - Publicaci\u00f3n de art\u00edculos, casos cl\u00ednicos, etc. de Medicina, Enfermer\u00eda y Ciencias de la Salud\",\"publisher\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#organization\"},\"alternateName\":\"Revista de PortalesMedicos\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#organization\",\"name\":\"Revista Electr\u00f3nica de Portales Medicos.com\",\"alternateName\":\"Revista de PortalesMedicos\",\"url\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/logorevista_negro.jpg\",\"contentUrl\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/logorevista_negro.jpg\",\"width\":199,\"height\":65,\"caption\":\"Revista Electr\u00f3nica de Portales Medicos.com\"},\"image\":{\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/person\/aff35293bfdd1e8bb11bc1d216ac2c6e\",\"name\":\"Redacci\u00f3n Revista\",\"sameAs\":[\"https:\/\/x.com\/portalesmedicos\"],\"url\":\"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/author\/pmedadmin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)","description":"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS) Resumen: El \u00edndice biesprectal (BIS) es un sistema no invasivo de monitorizaci\u00f3n","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/","next":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/2\/","twitter_misc":{"Escrito por":"Redacci\u00f3n Revista","Tiempo de lectura":"4 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"ScholarlyArticle","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#article","isPartOf":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/"},"author":{"name":"Redacci\u00f3n Revista","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/person\/aff35293bfdd1e8bb11bc1d216ac2c6e"},"headline":"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)","datePublished":"2015-09-26T20:57:42+00:00","dateModified":"2015-09-26T20:58:58+00:00","mainEntityOfPage":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/"},"wordCount":761,"publisher":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#organization"},"image":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg","keywords":["biespectral","BIS","monitor","sedaci\u00f3n","sensor"],"articleSection":["Enfermer\u00eda"],"inLanguage":"es"},{"@type":["WebPage","ItemPage"],"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/","url":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/","name":"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS)","isPartOf":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage"},"image":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage"},"thumbnailUrl":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg","datePublished":"2015-09-26T20:57:42+00:00","dateModified":"2015-09-26T20:58:58+00:00","description":"Atenci\u00f3n de Enfermer\u00eda en la monitorizaci\u00f3n del \u00cdndice Biespectral (BIS) Resumen: El \u00edndice biesprectal (BIS) es un sistema no invasivo de monitorizaci\u00f3n","breadcrumb":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#primaryimage","url":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg","contentUrl":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/4-sensor-BIS.jpg","width":388,"height":386,"caption":"Colocaci\u00f3n sensor BIS"},{"@type":"BreadcrumbList","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/enfermeria-monitorizacion-bis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/"},{"@type":"ListItem","position":2,"name":"Enfermer\u00eda"}]},{"@type":"WebSite","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#website","url":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/","name":"Revista Electr\u00f3nica de PortalesMedicos.com","description":"ISSN 1886-8924 - Publicaci\u00f3n de art\u00edculos, casos cl\u00ednicos, etc. de Medicina, Enfermer\u00eda y Ciencias de la Salud","publisher":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#organization"},"alternateName":"Revista de PortalesMedicos","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#organization","name":"Revista Electr\u00f3nica de Portales Medicos.com","alternateName":"Revista de PortalesMedicos","url":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/logo\/image\/","url":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/logorevista_negro.jpg","contentUrl":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-content\/uploads\/logorevista_negro.jpg","width":199,"height":65,"caption":"Revista Electr\u00f3nica de Portales Medicos.com"},"image":{"@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/#\/schema\/person\/aff35293bfdd1e8bb11bc1d216ac2c6e","name":"Redacci\u00f3n Revista","sameAs":["https:\/\/x.com\/portalesmedicos"],"url":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/author\/pmedadmin\/"}]}},"views":15173,"_links":{"self":[{"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/posts\/34515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/comments?post=34515"}],"version-history":[{"count":0,"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/posts\/34515\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/media\/34519"}],"wp:attachment":[{"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/media?parent=34515"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/categories?post=34515"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.revista-portalesmedicos.com\/revista-medica\/wp-json\/wp\/v2\/tags?post=34515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}